A kill sheet ties every well-control number together: kill weight, circulating pressures, string and annular volumes, strokes and a step-down schedule so the choke operator knows exactly what drill pipe pressure to hold as kill mud goes down the string.

Formulas

String volumeV = Σ (ID² / 1029.4) × length
Strokes surface to bitSTB = String volume / Pump output
Pressure step-downΔP per step = (ICP − FCP) / number of steps

Worked example

GIVEN
  • 10,000 ft of 5" 19.5# DP (ID 4.276")
  • Pump output = 0.100 bbl/stk
  • ICP = 1,120 psi, FCP = 659 psi
WORKING
  1. Capacity = 4.276² / 1029.4 = 0.01776 bbl/ft
  2. String volume = 0.01776 × 10,000 = 177.6 bbl
  3. STB = 177.6 / 0.1 = 1,776 stk
  4. 10 steps → drop ≈ 46 psi every 178 strokes
1,776 strokes to bit, DP pressure falls from 1,120 to 659 psi

FAQ

Driller's method or Wait & Weight?

The schedule here is for Wait & Weight (one circulation). For the Driller's method, hold ICP constant on the first circulation, then follow the schedule with kill mud on the second.

Can I print it for the doghouse?

Yes — Pro users can export the kill sheet as a PDF report.

Run it with your well data
Field & Metric units, works offline, save and share results with your crew.
RELATED

Reference only. Always verify against your company procedures and well-control certification.